Power & Data Centre

From one rack in a branch office to a containerised data centre. Sized to your load schedule, installed, commissioned under load, and maintained.

Switchgear and power distribution in a plant room
Switchgear and power distribution in a plant room
Data hall white space — racks, containment and cabling
Data hall white space — racks, containment and cabling
VRLA battery bank, sized to the autonomy you specify
VRLA battery bank, sized to the autonomy you specify
Step 01

Survey and sizing

Load schedule, autonomy, redundancy and growth. We size to the next standard frame, not to the number that sells the biggest unit.

Step 02

Supply

Equipment against the approved submittal, with datasheets and certificates the consultant will sign.

Step 03

Installation

Positioning, battery racking, DC and AC termination, containment and integration with the switchboard.

Step 04

Commissioning

Load bank testing, transfer verification, alarm proving, handover documentation and operator training.

Uninterruptible power

Every class of UPS, from the desk to the data hall.

Single phase

ClassRatingTopology & format
Line interactive, tower400 VA – 3 kVADesks, tills, small comms cabinets
Line interactive, wide input600 VA – 3 kVAWeak or generator-backed supply
Line interactive, pure sine1 – 2 kVAFor equipment with active PFC power supplies
Online double conversion, tower700 VA – 3 kVAFull isolation from the incoming supply
Online double conversion, rack or tower3 – 11 kVALead-acid or lithium battery
Online double conversion, rack-mount6 – 10 kVAUp to 94% efficiency
Modular, rack or tower4 – 20 kVAN+X redundancy inside one frame

Three phase and modular

ClassRatingNotes
Online double conversion10 – 40 kVAUp to 95.5% efficiency
Online double conversion50 – 200 kVAUp to 95.8% efficiency
Modular, rack format10 – 50 kVAUnity power factor
Modular subrack10 – 150 kVAUp to 96% efficiency, unity power factor
Modular cabinet40 – 1000 kVAUp to 96% efficiency, hot-swap power modules
Modular, high efficiency30 – 500 kVAUp to 97% in double conversion; 380/400/415 V; VRLA, lithium or supercapacitor
Tower200 – 1200 kVALarge data-centre class
Marine and offshore duty30 – 200 kVABuilt for shipboard and offshore installation

Ratings shown are the published ranges of the series we supply in this region. Exact frame, efficiency class and battery configuration are confirmed on the quotation against your load schedule.

Batteries

The part that fails first, and the part nobody budgets for.

A UPS is only as good as the string behind it. Lead-acid, gel, high-rate, deep-cycle and lithium — sized to the autonomy you need, with a replacement programme so it is changed before it fails.

TypeCapacityVolt
General purpose VRLA1.2 – 250 Ah2 V
High rate55 – 150 Ah12 V
Long duration cells100 – 3000 Ah2 V
Standby blocks36 – 200 Ah6 / 12 V

Also supplied: deep cycle, high rate, gel and LiFePO4 lithium. Larger systems can be specified with VRLA, lithium-ion or supercapacitor storage, and with battery management that charges in stages to extend service life.

Data centre

Power, cooling, containment and the rack it all sits in.

We deliver data-centre projects turnkey — design support, supply, installation, commissioning and handover — or supply any part of it against someone else's design.

Precision cooling

Room cooling from 5 to 20 kW and from 25 to 300 kW, air-cooled or chilled water, plus in-row, rack-mounted and outdoor condenser formats.

Modular & containerised

Integrated power, distribution, battery, cooling, fire protection and cabinets — deployable where a conventional room is not practical.

Rack PDUs

Basic, metered, metered-outlet and switched, single and three phase, roughly 1.4 to 46 kW, 0U vertical or horizontal, cascadable up to 40 units.

Racks & monitoring

IT racks rated to 500 kg dynamic load with cable management and baying kits, and power-management software for remote monitoring and graceful shutdown.

PDU platforms supplied carry UL 2900-1 and IEC 62443-4-2 cybersecurity certification, which is increasingly a requirement in Saudi data-centre tenders.

Tools

Size the system before you call us.

Indicative, not a substitute for a survey — but they get you to the right order of magnitude before the meeting.

Power factor 0.9 is a reasonable default for mixed IT and mechanical load. Modern modular UPS is unity power factor, so kVA and kW are the same number at the output.

Indicative sizing

Apparent power at the load kVA
With growth allowance kVA
Next standard frame kVA
Units required
Battery string × 12 V blocks
Installed capacity kVA
Approximate battery capacity Ah

Vertical cylindrical vessel with two identical ends. For a jacketed vessel the figure below is the inner product volume, not the jacket.

Geometric capacity

Straight shell L
Both ends L
Total, in cubic metres
Total capacity L
Working volume at chosen fill L
Start here

Send us the specification, the drawing or the load schedule. A written offer follows within two working days — make, model, lead time and terms, in writing.

Start an enquiry